46.7 Peripheral Active Current
DC CHARACTERISTICS (1) | Standard Operating Conditions: VDD and
VDDIO 2.7V to 5.5V (unless otherwise stated) Operating temperature: -40°C ≤ TA ≤ +85°C for Industrial | ||
---|---|---|---|
Param. No. | Symbol | Characteristics | Conditions |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 1.5 µA | |||
PAI_10 | IOSC32K | OSC32K current | AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 2 µA | |||
PAI_20 | IXOSC32K | XOSC32K current | AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 75 µA | |||
PAI_30 | IBODVDD | BODVDD Active current | Continuous mode, AVDD = VDDIO = 5.0V |
PAI_33 | IEVSYS | EVSYS Active current | One channel operating, Synchronous mode |
PAI_36 | ICCL | CCL Active current | All LUT Active, Filter Enabled |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 100 µA | |||
PAI_40 | IWDT | WDT Active current | — |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 200 µA | |||
PAI_50 | IOSC48M | OSC48M current | AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 250 µA | |||
PAI_60 | IXOSC_2MHZ_AMPGC_ON | XOSC current (1 of 10) | F = 2 MHz - CL = 20 pF XOSC.GAIN = 0, AMPGC = ON, AVDD = VDDIO = 5.0V |
PAI_62 | IXOSC_2MHZ_AMPGC_OFF | XOSC current (2 of 10) | F = 2 MHz - CL = 20 pF XOSC.GAIN = 0, AMPGC = OFF, AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 300 µA | |||
PAI_70 | ITC4/5/6/7 | TC Active current (1 of 2) | Normal Frequency mode, Counter in 16 bits mode |
PAI_72 | ICANx | CANx Active current | No Communication |
PAI_74 | IAC | AC Active current | COMP0 and COMP1 operating in low speed, Vscaler0 = Vscaler1 = AVDD |
PAI_76 | IXOSC_4MHZ_AMPGC_ON | XOSC current (3 of 10) | F = 4 MHz - CL = 20 pF XOSC.GAIN = 1, AMPGC = ON, AVDD = VDDIO = 5.0V |
PAI_78 | IXOSC_4MHZ_AMPGC_OFF | XOSC current (4 of 10) | F = 4 MHz - CL = 20 pF XOSC.GAIN = 1, AMPGC = OFF, AVDD = VDDIO = 5.0V |
PAI_80 | IPDEC | PDEC Active current | Counter Mode |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 350 µA | |||
PAI_90 | IXOSC_8MHZ_AMPGC_ON | XOSC current (5 of 10) | F = 4 MHz - CL = 20 pF XOSC.GAIN = 1, AMPGC = ON, AVDD = VDDIO = 5.0V |
PAI_93 | ITCC2 | TCC Active Current (1 of 2) | Normal Frequency mode |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 400 µA | |||
PAI_100 | ITC0/1/2/3 | TC Active current (2 of 2) | Normal Frequency mode, Counter in 16 bits mode |
PAI_102 | IEIC | EIC/NMI Active current | One EIC line operating, Filter Enabled |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 450 µA | |||
PAI_110 | IXOSC_8MHZ_AMPGC_OFF | XOSC current (6 of 10) | F = 8 MHz - CL = 20 pF XOSC.GAIN = 2, AMPGC = OFF, AVDD = VDDIO = 5.0V |
PAI_112 | ISERCOMx | SERCOM Active current | USART Mode, no communication |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 550 µA | |||
PAI_120 | IDAC (2) | DAC Active current | VREF = AVDD, DAC DATA = 0x3FF |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 700 µA | |||
PAI_130 | IDPLL48M | DPLL Current (1 of 2) | Fout = 48 MHz, AVDD = VDDIO = 5.0V |
PAI_133 | IXOSC_16MHZ_AMPGC_ON | XOSC current (7 of 10) | F = 16 MHz - CL = 20 pF XOSC.GAIN = 3, AMPGC = ON, AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 750 µA | |||
PAI_140 | IPTC | PTC Active current | Free-Running mode |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 900 µA | |||
PAI_150 | IXOSC_16MHZ_AMPGC_OFF | XOSC current (8 of 10) | F = 16 MHz - CL = 20 pF XOSC.GAIN = 3, AMPGC = OFF, AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 1 mA | |||
PAI_160 | IDPLL96M | DPLL Current (2 of 2) | Fout = 96 MHz, AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 1.2 mA | |||
PAI_165 | IFREQM (3) | FREQM Active current | Reference running at 48 MHz and Measure clock running at 96 MHz |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 1.5 mA | |||
PAI_170 | IXOSC_32MHZ_AMPGC_ON | XOSC current (9 of 10) | F = 32 MHz - CL = 12 pF XOSC.GAIN = 4, AMPGC = ON, AVDD = VDDIO = 5.0V |
PAI_172 | IADC (4) | ADC Active current | Free-Running, 1 Msps, AVDD = VREF = 5,5V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 2 mA | |||
PAI_180 | ITCC0/1 (3) | TCC Active Current | Normal Frequency mode |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 3 mA | |||
PAI_190 | IXOSC_32MHZ_AMPGC_OFF | XOSC current (10 of 10) | F = 32 MHz - CL = 12 pF XOSC.GAIN = 4, AMPGC = OFF, AVDD = VDDIO = 5.0V |
MODULES/PERIPHERALS ACTIVE CURRENTS ≤ 5.5 mA | |||
PAI_200 | IDMA | DMA Active current | RAM-to-RAM transfer, one channel operating |
Note:
- Conditions:
- Only mentioned peripheral modules is operating (i.e., rest of the peripherals are inactive)
- MCLK all APB clock masked except MCLK and NVMCTRL and selected peripheral
- MCLK.AHBMASK = 0x00C00FFF
- All clock generation sources disabled unless otherwise specified. (i.e., XOSC32K = Off)
- All clock sources disabled except XOSC32K running with external 32 kHz crystal and FDPLL96M using XOSC32K as reference and running at 96 MHz divided by 2 on GCLK0
- GCLK clock generators 1 to 8 stopped (GENCTRL[8:1].GENEN = 0)
- AHB/APB clocks not needed are masked: AHBMASK = 0x70, APB(A/B/C/D)MASK = 0x0
- CPU and AHB clocks undivided
- I/Os are inactive input mode with input trigger disabled
- WDT, RTC, CFD Clock Fail Detect disabled
- RESET = VDDIO
- CPU is running on Flash with three Wait States
- NVMCTRL cache enabled
- BODVDD disabled
- Measure is differential between active and inactive module in those conditions
- Conditions:
- Same Conditions as Note 1
- GCLK1 running on FDPLL96M at 96 MHz divided by 96
- Measure is differential between active and inactive module in those conditions
- Conditions:
- Same Conditions as Note 1
- GCLK1 running on FDPLL96M at 96 MHz not divided
- Measure is differential between active and inactive module in those conditions
- Conditions:
- Same Conditions as Note 1
- GCLK1 running on FDPLL96M at 96 MHz divided by 6
- Measure is differential between active and inactive module in those conditions