55.14 Maximum Clock Frequencies Electrical Specifications

Table 55-18. Maximum Clock Frequencies Electrical Specifications
AC CHARACTERISTICS Standard Operating Conditions: VDD = AVDD = 1.71V to 3.63V (unless otherwise stated)

Operating temperature:

-40°C ≤ TA ≤ +85°C for Industrial Temperature

Param. No.SymbolCharacteristicsMax.Units
FCLK_1fCPUCPU clock freq120MHz
FCLK_3fAHBAHB clock freq120MHz
FCLK_5fAPBxAPBA, APBB, APBC, APBD clock freq120MHz
FCLK_6fHSHigh Speed (HS) clock freq132MHz
FCLK_7fGCLK_DPLLxFDPLL0 and FDPLL1 reference clock freq3.2MHz
FCLK_9fGCLK_DPLLx_32KFDPLL0 and FDPLL1 32k reference clock freq100MHz
FCLK_11fGCLK_DFLL48M_REFDFLL48M reference clock freq33kHz
FCLK_13fGCLK_EICEIC input clock freq100MHz
FCLK_15fGCLK_FREQM_MSRFREQM Measure Clock Freqency200MHz
FCLK_17fGCLK_FREQM_REFFREQM Reference Clock Frequency100MHz
FCLK_19fGCLK_EVSYS_CHANNELxEVSYS channel x input clock freq100MHz
FCLK_21fGCLK_SERCOMx_SLOWCommon SERCOM slow input clock freq12MHz
FCLK_23fGCLK_SERCOMx_CORESERCOMx input clock freq100MHz
FCLK_25fGCLK_CANxCAN input clock freq100MHz
FCLK_27fGCLK_USBUSB input clock freq60MHz
FCLK_29fGCLK_I2SI2S input clock freq100MHz
FCLK_31fGCLK_SDHCx_SLOWCommon SDHC slow input clock freq12MHz
FCLK_33fGCLK_SDHCx_CORESDHCx input clock freq150MHz
FCLK_35fGCLK_TCCxTCCx input clock freq200MHz
FCLK_37fGCLK_TCxTC0, TC1, TC2, TC3 input clock freq200MHz
FCLK_39fGCLK_TCxTC4, TC5, TC6, TC7 input clock freq100MHz
FCLK_41fGCLK_PDECPDEC input clock freq200MHz
FCLK_43fGCLK_CCLCCL input clock freq100MHz
FCLK_45fGCLK_GCLKINxExternal GCLKx input clock freq50MHz
FCLK_47fGCLK_CM4_TRACECortex-M4 Trace input clock freq120MHz
FCLK_49fGCLK_ACAnalog comparator peripheral module clock freq100MHz
FCLK_51fGCLK_ADCxADCx input clock freq100MHz
FCLK_53fGCLK_DACDAC input clock freq100MHz