14.3.26 ADC Channel Trigger 1 Selection Register High
| Name: | ADTRIG1H |
| Offset: | 0xB86 |
| Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | |
| TRGSRC7[4:0] | |||||||||
| Access | R/W | R/W | R/W | R/W | R/W | ||||
| Reset | 0 | 0 | 0 | 0 | 0 | ||||
| Bit | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |
| TRGSRC6[4:0] | |||||||||
| Access | R/W | R/W | R/W | R/W | R/W | ||||
| Reset | 0 | 0 | 0 | 0 | 0 | ||||
Bits 12:8 – TRGSRC7[4:0] Trigger Source Selection for Corresponding Analog Inputs bits
| Value | Description |
|---|---|
11111 |
ADTRG31 (PPS input) |
11110 |
PTG |
11101 |
CLC2 |
11100 |
CLC1 |
11011 |
Input Capture/Output Compare 9 |
11010 |
Input Capture/Output Compare 7 |
11001 |
Input Capture/Output Compare 6 |
11000 |
Input Capture/Output Compare 5 |
10111 |
Input Capture/Output Compare 4 |
10110 |
Input Capture/Output Compare 3 |
10101 |
Input Capture/Output Compare 2 |
10100 |
Input Capture/Output Compare 1 |
10011 |
PWM8 Trigger 2 |
10010 |
PWM8 Trigger 1 |
10001-10000 |
Reserved |
01111 |
PWM6 Trigger 2 |
01110 |
PWM6 Trigger 1 |
01101-01100 |
Reserved |
01011 |
PWM4 Trigger 2 |
01010 |
PWM4 Trigger 1 |
01001 |
PWM3 Trigger 2 |
01000 |
PWM3 Trigger 1 |
00111 |
PWM2 Trigger 2 |
00110 |
PWM2 Trigger 1 |
00101 |
PWM1 Trigger 2 |
00100 |
PWM1 Trigger 1 |
00011 |
Reserved |
00010 |
Level software trigger |
00001 |
Common software trigger |
00000 |
No trigger is enabled |
Bits 4:0 – TRGSRC6[4:0] Common Interrupt Enable for Corresponding Analog Inputs bits
| Value | Description |
|---|---|
11111 |
ADTRG31 (PPS input) |
11110 |
PTG |
11101 |
CLC2 |
11100 |
CLC1 |
11011 |
Input Capture/Output Compare 9 |
11010 |
Input Capture/Output Compare 7 |
11001 |
Input Capture/Output Compare 6 |
11000 |
Input Capture/Output Compare 5 |
10111 |
Input Capture/Output Compare 4 |
10110 |
Input Capture/Output Compare 3 |
10101 |
Input Capture/Output Compare 2 |
10100 |
Input Capture/Output Compare 1 |
10011 |
PWM8 Trigger 2 |
10010 |
PWM8 Trigger 1 |
10001-10000 |
Reserved |
01111 |
PWM6 Trigger 2 |
01110 |
PWM6 Trigger 1 |
01101-01100 |
Reserved |
01011 |
PWM4 Trigger 2 |
01010 |
PWM4 Trigger 1 |
01001 |
PWM3 Trigger 2 |
01000 |
PWM3 Trigger 1 |
00111 |
PWM2 Trigger 2 |
00110 |
PWM2 Trigger 1 |
00101 |
PWM1 Trigger 2 |
00100 |
PWM1 Trigger 1 |
00011 |
Reserved |
00010 |
Level software trigger |
00001 |
Common software trigger |
00000 |
No trigger is enabled |